Monokot Server 1.x
  • What is Monokot Server?
  • Quickstart
  • 🐸Basics
    • Supported OS and Hardware
    • Installation
    • Licensing
    • OPC UA
      • UA TCP Endpoint
      • UA Settings
      • Client Certificates
      • Aliases
      • Access to Object Settings
      • Troubleshooting
    • Security Certififcate
    • Users & Roles
    • Administrator GUI
      • Event Log
      • Users in Monokot Server Administrator
      • Roles in Monokot Server Administrator
    • Startup Parameters
  • 🦊Tags & Devices
    • Devices
      • Diagnostics
      • Devices in the Monokot Server Administrator
    • Tags
      • Parameters
      • Change Trigger
      • Tags in Monokot Server Administrator
        • Go Online
        • Group Action
        • Import & Export
    • Modbus Connectivity
      • Parameters
      • Addressing
      • Diagnostics
    • Siemens Connectivity
      • Parameters
      • Addressing
      • Access to DBs area in S7-1200/S7-1500
    • IEC 60870-5-104 Connectivity
      • Parameters
      • Addressing
      • Time Conversion
      • Diagnostics and Commands
    • OPC UA Connectivity
      • Parameters
      • Addressing
      • Diagnostics
      • How to: Importing OPC UA items
      • How to: Pulling Security Certificate
    • InfluxDB Connectivity (Connector)
      • Parameters
      • Addressing
      • Query Result and Data Mapping
      • Diagnostics
      • How to: Configure for InfluxDB 2.x
    • SNMP Connectivity
      • Parameters
      • Addressing
      • UDP Considerations
  • 🐺Time Series & Stores
    • Stores
      • Backlog
      • Diagnostics
      • Stores in Monokot Server Administrator
    • Time Series
      • Parameters
      • Deadband
      • Sampling
      • Last Sample Repeat
      • Time Series in Monokot Server Administrator
        • Group Action
        • Import & Export
    • InfluxDB Connectivity (Store)
      • Parameters
      • Addressing
      • Data Structure
      • About Metadata
      • Diagnostics
      • How to: Configure for InfluxDB 2.x
    • PostgreSQL Connectivity
      • Parameters
      • Addressing
      • Database Design
      • Data Compression
    • REST Connectivity
      • Parameters
      • Addressing
      • Message Script
      • RestRequestMessage
      • DataContext
      • TimeSeries
  • 🐻Scripts
    • Overview
    • Expression
      • Parameters
      • Import & Export
      • Go Online
    • Programming Examples
      • How to: Calculate Arithmetic Mean
      • How to: DoNothing
      • How to: Writing to Tag
      • How to: Inverting Bits
      • How to: Execute SQL
      • How to: Run Ping
      • How to: Do Simulation
      • How to: String Formatting
      • How to: OPC UA Method
      • How to: Initialize Device Settings from File
    • API
      • Bundle
      • BundlePair
      • Context
      • DataMap
      • DataMapPair
      • DataTriggerInfo
      • Expression
      • MosCrypto
      • MosDirectories
      • MosFiles
      • MosOdbc
      • MosOdbcReader
      • MosProcess
      • MosProcessExecuteResult
      • MosText
      • MosUtils
      • ValueState
Powered by GitBook
On this page
  1. Tags & Devices
  2. Tags

Change Trigger

Change Trigger

Change trigger specifies what changes the tag should notify all "interested" consumers about (OPC UA variable, time series, etc.). The following values are available:

  • StatusValue ensures the best performance, because in this mode the notifications are only sent after a change of status (for example, when the connection is lost) or value.

  • StatusValueTimestamp is the most resource-intensive notification mode. In this mode, the tag will signal its change with the frequency specified in the Update Rate, regardless of whether the status or value of the tag has changed or not.

Change trigger affects the amount of data saved in the store if the tag is associated to a time series, as well as the filtering mode for OPC UA subscription.

PreviousParametersNextTags in Monokot Server Administrator