Monokot Server 1.x
  • What is Monokot Server?
  • Quickstart
  • 🐸Basics
    • Supported OS and Hardware
    • Installation
    • Licensing
    • OPC UA
      • UA TCP Endpoint
      • UA Settings
      • Client Certificates
      • Aliases
      • Access to Object Settings
      • Troubleshooting
    • Security Certififcate
    • Users & Roles
    • Administrator GUI
      • Event Log
      • Users in Monokot Server Administrator
      • Roles in Monokot Server Administrator
    • Startup Parameters
  • 🦊Tags & Devices
    • Devices
      • Diagnostics
      • Devices in the Monokot Server Administrator
    • Tags
      • Parameters
      • Change Trigger
      • Tags in Monokot Server Administrator
        • Go Online
        • Group Action
        • Import & Export
    • Modbus Connectivity
      • Parameters
      • Addressing
      • Diagnostics
    • Siemens Connectivity
      • Parameters
      • Addressing
      • Access to DBs area in S7-1200/S7-1500
    • IEC 60870-5-104 Connectivity
      • Parameters
      • Addressing
      • Time Conversion
      • Diagnostics and Commands
    • OPC UA Connectivity
      • Parameters
      • Addressing
      • Diagnostics
      • How to: Importing OPC UA items
      • How to: Pulling Security Certificate
    • InfluxDB Connectivity (Connector)
      • Parameters
      • Addressing
      • Query Result and Data Mapping
      • Diagnostics
      • How to: Configure for InfluxDB 2.x
    • SNMP Connectivity
      • Parameters
      • Addressing
      • UDP Considerations
  • 🐺Time Series & Stores
    • Stores
      • Backlog
      • Diagnostics
      • Stores in Monokot Server Administrator
    • Time Series
      • Parameters
      • Deadband
      • Sampling
      • Last Sample Repeat
      • Time Series in Monokot Server Administrator
        • Group Action
        • Import & Export
    • InfluxDB Connectivity (Store)
      • Parameters
      • Addressing
      • Data Structure
      • About Metadata
      • Diagnostics
      • How to: Configure for InfluxDB 2.x
    • PostgreSQL Connectivity
      • Parameters
      • Addressing
      • Database Design
      • Data Compression
    • REST Connectivity
      • Parameters
      • Addressing
      • Message Script
      • RestRequestMessage
      • DataContext
      • TimeSeries
  • 🐻Scripts
    • Overview
    • Expression
      • Parameters
      • Import & Export
      • Go Online
    • Programming Examples
      • How to: Calculate Arithmetic Mean
      • How to: DoNothing
      • How to: Writing to Tag
      • How to: Inverting Bits
      • How to: Execute SQL
      • How to: Run Ping
      • How to: Do Simulation
      • How to: String Formatting
      • How to: OPC UA Method
      • How to: Initialize Device Settings from File
    • API
      • Bundle
      • BundlePair
      • Context
      • DataMap
      • DataMapPair
      • DataTriggerInfo
      • Expression
      • MosCrypto
      • MosDirectories
      • MosFiles
      • MosOdbc
      • MosOdbcReader
      • MosProcess
      • MosProcessExecuteResult
      • MosText
      • MosUtils
      • ValueState
Powered by GitBook
On this page
  1. Tags & Devices
  2. OPC UA Connectivity

How to: Pulling Security Certificate

PreviousHow to: Importing OPC UA itemsNextInfluxDB Connectivity (Connector)

Last updated 2 years ago

To pull the security certificate of an external OPC UA server and place it to the certificate list using Monokot Server Administrator, open the Device Manager, select the OPC UA Client device used for communication with the external OPC UA server and click Pull The Certificate.

In the following dialog box, click Yes, and the certificate will appear in the certificate list on the Server Certificates tab. To make the added certificate trusted, select it from the certificate list and click the Trust button.

For the changes to take effect, they need to be synchronized with the server by pressing the Sync button or the F5 key.

🦊